Nick Pine proposes a solar home heating concept using solar heating system that is aimed at producing a very high solar fraction with relatively inexpensive solar air heating collectors. In order to accomplish the high solar fraction, the system must include several days worth of heat storage for extended cloudy periods -- a large storage capacity. The physical size of this large heat storage depends on the maximum temperature that the storage can be raised to -- higher temperatures store more heat in less space. But, producing higher temperatures normally means that the solar air heating collectors would operate less efficiently as the losses out the collector glazing go up with collector temperature -- thus the desire for high storage temperatures can result in an undesirable increase in collector area. There is a potential collector design that may produce the desirable higher collector temperatures at good efficiency. This design uses several layers of mesh for the absorber. The advantages are said to be: 1) the pressure drop caused by the mesh spreads the airflow evenly over the full surface of the absorber, and 2) the first layer of mesh acts as a radiation shield to reduce the radiation from the hotter inner layers toward the glazing. The first layer of mesh runs relatively cool in part because in this heating scheme, the air introduced into the collector is relatively cool (70F) room air -- this cooler first layer of mesh thus reduces losses out the glazing. So, in an ideal design, 70 F room temperature air is introduced between the glazing and the first (south most) layer of mesh. This coolish air spreads evenly over the full mesh surface because of the mesh pressure drop. Even though the airflow rate is low (to achieve higher temperatures), the first layer of mesh runs at a low temperature because of the relatively cool 70F air, and the ability of the mesh absorbers to provide very even airflow over the full surface. As the air progresses through the layers of mesh, it heats up, and since flow rate is low, the residence time is long and the air heats up to high temperatures (say 140+F). This hot air is then passed through an air to water heat exchanger and the hot water produced goes to heating the heat storage. By using the hottest air to heat the storage, the max storage temperature can be higher and it can store more heat. The still warm air leaves the heat exchanger and is blown into the house for immediate space heating. A key element in making this scheme work is the low flow, deep mesh collector that operates efficiently while producing high temperatures. This test is a starting point in trying to see if this can be accomplished in a collector that is straight forward and inexpensive to build. My standard air heating collector which has just 3 layers of aluminum screen mesh is the starting point. The idea is to see how well it does in achieving the high temperatures AND high efficiency, and to identify changes that might make it do better, and possibly test those. On this page: - Results (temperatures, flow rates, heat out, efficiency, glazing temperature) |
The collector used for the test is 4 by 8 feet. Glazing is 10mm thick twinwall polycarbonate. The absorber is three layers of black aluminum insect screen -- the layers are spaced 3/8 inch apart. The absorber is tilted such that it is furthest from the glazing at the bottom and closer to the glazing at the top. The back insulation is 2 inch polyisocyanurate painted black on the south surface. The inlet is at the center bottom of the collector -- all of the air is introduced on the glazing side of the absorber. A full width deflector keeps the inlet air from impinging directly onto the glazing and (hopefully) spreads the air out over the full width. The exit vent is at the top center. The exit vent is on the north side of the layers of mesh, so that all of the air has to pass through all layers of mesh to get from inlet to outlet. Both vents are 6 inch diameter circles. The top and bottom of the twinwall glazing is taped over with aluminum tape to prevent airflow through the internal channels.
The collector is much like this one... The differences being the twinwall glazing, and some changes to the airflow deflector at the inlet. Some pictures:
The collector is mounted on a stand just outside the shop main door tilted at about 70 degrees. The collector azimuth can be adjusted to face the sun during the day. The inlet and outlet ducts are brought back to the shop using 6 inch diameter HVAC flex ducts that are insulated.
An Apogee pyranometer is mounted to the collector about half way up and in the plane of the collector glazing.
Inside the shop, the a blower was setup to suck air from the collector exit vent into the shop. A speed control was used to adjust the blower speed and flow rate.
Most of the ducting is 6 inch diameter, but is stepped down to 5 inches at the fan. The fan outlet duct is also 5 inches, and that duct exit is where the air velocity is measured.
The collector pressure drop is measured between static ports in the rigid 6 inch duct sections, so the collector pressure drop includes the drop due to about 20 ft of the flex ducting.
The duct inlet and outlet temperatures are made in ducts using thermistors that are logged on Onset Computer U12 loggers. The thermistors are low mass, fast acting. They are secured near the centerline of the ducts.
Data was taken for flow rates of 4.3, 3.3, 2.1 and 1.5 cfm per sf of collector area. Several readings were taken at each flow rate at intervals of 3 to 5 minutes. The sun was generally good, but there were some high thin clouds moving in and out -- I tried to pick periods of relatively constant sun intensity for each flow rate run. Sun levels were high (up to 1200 watt/sm) due to the clear air and reflective snow in front of collector.
There was a reflective snow field in front of the collector for the test. |
The sun was generally good, but occasional high thin clouds did come in. |
The spreadsheet below gives the measured data and the calculated flow rate, heat out, solar in, and efficiency for all of the runs.
Initial test of the low flow, high temperature, dense mesh solar air heating collector. | |||||||||||||
1/16/2012 | Outlet Area | 0.136 | sf | ||||||||||
This is the 4 by 8 ft collector, 3 alum screen absorber, black back wall, glazed with twin wall | avg density | 0.061 | lb/cf | ||||||||||
Weather was sunny, cold, fresh snow on ground in front of collector -- some parts with wn | Col Area | 32 | sf | ||||||||||
Heat Cap air | 0.24 | BTU/lb-F | |||||||||||
F | F | F | F | ft/min | watt/sm | ft/min | cfm | cfm/sf | F | BTU/hr | BTU/hr | ||
Time | Tambient | Tin | Tout | Tglaz | Velocity | Sun | Vin | Total flow | Flow/sf | Temp Rise | Solar In | Heat Out | "Efic" |
12:37 PM | start test -- logger btn press -- maximum flow rate | ||||||||||||
12:37 PM | 16 | 55.9 | 97.1 | 72 | 1003 | 1159 | 894 | 136.4 | 4.3 | 41.2 | 11761 | 4937 | 42.0% |
12:41 PM | 16 | 55.8 | 96.7 | 72.7 | 982 | 1158 | 945 | 133.6 | 4.2 | 40.9 | 11750 | 4798 | 40.8% |
12:45 PM | 16 | 56.4 | 96.5 | 70.9 | 1040 | 1154 | 922 | 141.4 | 4.4 | 40.1 | 11710 | 4982 | 42.5% |
12:47 PM | Reduce flow rate --logger btn press abouit 3.2 cfm/sf | ||||||||||||
12:49 PM | 16.5 | 55.7 | 108.5 | 72.1 | 780 | 1152 | 660 | 106.1 | 3.3 | 52.8 | 11690 | 4920 | 42.1% |
12:52 PM | 16.5 | 55.2 | 109.5 | 72.7 | 765 | 1151 | 673 | 104.0 | 3.3 | 54.3 | 11679 | 4962 | 42.5% |
12:55 PM | 16.5 | 55.8 | 110.1 | 71.5 | 775 | 1160 | 665 | 105.4 | 3.3 | 54.3 | 11771 | 5027 | 42.7% |
1:00 PM | 16.5 | 55.7 | 113.2 | 73.3 | 796 | 1196 | 670 | 108.3 | 3.4 | 57.5 | 12136 | 5468 | 45.1% |
1:03 PM | 16.5 | 65.4 | 114.2 | 75.2 | 748 | 1204 | 660 | 101.7 | 3.2 | 48.8 | 12217 | 4361 | 35.7% |
1:04 PM | Reduce flow rate-- logger btn press about 2.1 cfm/sf | ||||||||||||
1:06 PM | 16 | 55.7 | 124.8 | 75.8 | 495 | 1130 | 67.3 | 2.1 | 69.1 | 11466 | 4086 | 35.6% | |
1:09 PM | 16 | 55.5 | 127 | 78.2 | 495 | 1105 | 67.3 | 2.1 | 71.5 | 11213 | 4228 | 37.7% | |
1:11 PM | 16 | 55.5 | 128.3 | 80.6 | 525 | 1186 | 71.4 | 2.2 | 72.8 | 12035 | 4566 | 37.9% | |
1:13 PM | 16.5 | 55.6 | 130 | 80.6 | 526 | 1182 | 71.5 | 2.2 | 74.4 | 11994 | 4675 | 39.0% | |
1:15 PM | IR pics 668 - 686 | ||||||||||||
1:19 PM | 16.5 | 55.6 | 130.4 | 510 | 1190 | 69.4 | 2.2 | 74.8 | 12075 | 4557 | 37.7% | ||
1:20 PM | Reduce flow rate -- logger btn press about 1.5 crm/sf | ||||||||||||
1:23 PM | 17 | 56.5 | 134.1 | 85.6 | 350 | 1185 | 47.6 | 1.5 | 77.6 | 12024 | 3245 | 27.0% | |
1:26 PM | 17 | 56.5 | 139.3 | 90.8 | 345 | 1190 | 46.9 | 1.5 | 82.8 | 12075 | 3413 | 28.3% | |
1:28 PM | 17 | 56.6 | 142 | 92 | 345 | 1200 | 46.9 | 1.5 | 85.4 | 12177 | 3520 | 28.9% | |
1:30 PM | 17 | 56.8 | 143.6 | 93.8 | 350 | 1233 | 47.6 | 1.5 | 86.8 | 12512 | 3629 | 29.0% | |
1:34 PM | IR pics 687 - 693 | ||||||||||||
2:19 PM | 22 | 55.6 | 112.1 | 71 | 338 | 823 | 46.0 | 1.4 | 56.5 | 8351 | 2281 | 27.3% | |
2:20 PM | btn push -- IR pics 694-704 |
Columns:
Tambient - ambient temperature measured 50 ft away.
Tin -- collector inlet temperature -- this was air drawn from the shop.
Tout -- collector outlet temperature
Tglaz -- Glazing outside surface temperature measured with a surface moutn thermocouple (see notes below on this)
Velocity -- velocity in ft/min measured at the end of the 5 inch fan outlet duct.
Sun -- Solar intensity in the plane of the collector watts/sm
Total flow -- Total outlet flow in cfm = (Veocity)*(Duct Area)
Flow/sf -- the flow rate per sqft of collector = (Total flow/32)
Temp Rise -- Temperature rise for the collector = Tout - Tin
Solar In -- Solar power into the collector = (Sun intensity)*(Collector area)
Heat Out -- heat power out of the collector = (Flow rate)*(Air density)*(Tout - Tin)*(60 min/hr)*(Heat Capacity of Air)
"Efic" -- Approximate efficiency = (Heat Out)/(Solar In) %
An air density of 0.061 lbs/cf was used -- this is corrected for our 5000 ft altitude and the average temperature of the collector air. This calculator was used...
One objective was to achieve large temperature rises and high output temperatures. At the lower flow rates, I'd say the collector does pretty well with output temps in the 140 F area -- these would have been more like 150 F had it not been for the relatively cool shop air that was used for collector input.
But, as the next section shows, the high output temps come as some expense in heat output and efficiency.
The plots show the collector heat output vs the collector temperature rise achieved, and the collector "Efficiency" vs the collector flow rate.
For the collector as is is now, there is a significant drop in efficiency and heat output to get the higher collector output temperatures. The heat output drops from about 5000 BTU/hr down to about 3500 BTU/hr -- a hit of about 30%. Maybe we can do better? How?
The IR pictures below show temperatures on the outer surface of the glazing for the tested airflows.
Cooler glazing temperatures would indicate that collector heated air is not working its way out to the glazing and warming it, and/or that the glazing was seeing less radiation heating from the absorber screens.
The three side by side IR pics below are with 3.3, 2.1 and 1.5 cfm/sf of
collector flow rates.
All done to a temperature scale of 10F to 80F.
No IR picture was taken for the 4.2 cfm/sf flow rate.
Flow Rate 3.3 cfm/sf |
Flow Rate 2.1 cfm/sf |
Flow Rate 1.5 cfm/sf |
Its clear that the glazing is getting hotter for each reduction in flow rate -- hotter glazing means more heat loss and lower efficiency.
Potential causes of the hotter glazing with lower airflows:
- Increased radiation from the screen to the glazing because the lower airflow does not cool the screen as well?
- Air that has been heated by going through the screens penetrating back into the area in front of the first screen?
- Non-uniform flow across the full screen area causes the screens in the low airflow areas (toward the top?) to heat up more and radiate/convect heat to the glazing?
- Or?
At any rate the picture of room air (55 F in this case) evenly flowing into the whole surface of the absorber from front to back and cooling the first screen layer and acting as a radiation shield does not appear to be happening in this collector.
Other things to note.
- It looks like there may be some leakage of cold ambient air into the collector under the glazing. The blue streak coming in at the upper left is actually colder (20F) than the shop air -- so it seems pretty likely this is a leak. Same may be true at a couple places along the bottom.
- In the pictures below, the area to the right of the new collector is my wall mounted solar water heating collector. It is also glazed with twinwall polycarbonate. The storage tank temperature for that system reached 139.5F by afternoon.
- See the section below on Glazing Temperature Puzzle for more on a small uncertainty in the glazing temperature pictures.
I did not measure the pressure drop on this test, but on a test a couple days before:
At a flow rate of 2.1 cfm/sf the pressure drop was 0.09 inches of water (22 pascal)
At a flow rate of 1.4 cfm/sf the pressure drop was 0.025 inches of water (6 pascal)
So, pressure drops are very low -- especially considering that these pressure drops include about 20 ft of the 6 inch flex duct, making the drop across the screen itself even lower. This pressure drop may be too low to get the desired even flow of the inlet air over the full absorber area.
So, what changes should be made to make the collector perform better at high temperatures?
- Work on understanding what is actually happening on this configuration, and what exactly is causing the high glazing temperatures?
- Try a more dense mesh absorber that would have a higher pressure drop with the hope that it would make for a more even flow across the full face of the absorber and cool the first layer of the mesh more effectively?
- Or ?
These are the same three pictures as above in the full size versions -- click on pictures for full size.
Flow Rate 3.3 cfm/sf
Flow Rate 2.1 cfm/sf
Flow Rate 1.5 cfm/sf
This shows the logger report for the temperatures and solar intensity.
Note that the ambient temperature sensor was poorly located and is reading too high. I used the manually read temperatures from a thermometer mounted on the north wall of the barn about 50 ft away instead. Note that at one point around 2:10 pm the solar readings exceed the pyranometers maximum of 1250 watts/sm and are truncated for a few minutes.
I was looking for a way to validate the temperatures of the glazing that the IR camera shows. Part of the reason for this is that I am having trouble finding a good value to use for the emissivity of the twinwall polycarbonate to plug into the camera. So, I 1) attached a surface mount thermocouple to the outside of the twinwall to measure the "actual" surface temperature, and 2) applied a roughly 1.5 by 1.5 inch piece of blue painters tape a few inches below the thermocouple -- this is the often used technique of placing a patch of something with know emissivity over an unknown emissivity surface, and then measure the temperature on the known patch.
So, for the painters tape, one might expect that the tape would reach the same temperature as the glazing, and if the glazing and tape had the same emissivity, they would show the same color on the IR pictures. Or, if one believed that the tape emissivity was about 0.95, one could read the tape temperature with the camera set at 0.95, then change the emissivity setting until the surrounding twinwall showed the same temperature.
Well, on the picture taken with the camera emissivity set to 0.95, the twinwall temp shows 54.4F and the painters tape 72.4F. There is no way to adjust the emissivity enough to get the twinwall up to 72.4 F or anywhere close. I am inclined to believe that the tape is actually running hotter because it is heating up from absorbed sunlight. It looks like its actually running nearly 20F hotter than the glazing. Does this seem reasonable?
IR picture showing painters tape (bright spot at 72.4F) on the twinwall
glazing with emissivity set to 0.95.
(he bar across the picture just above the tape is the glazing support just
inside the glazing).
Looking at the surface mounted thermocouple, there are three values that can be compared (see picture below):
- the thermocouple reading 81F (from the logger plot)
- the IR camera temperature reading on the thermocouple 80F
- the IR camera temperature reading on the twinwall near the thermocouple 54.4F
So, the IR camera and the actual thermocouple reading agree well, but the twinwall glazing surface temperature is reported to be about 25 F lower. Again, there is no way to adjust the emissivity setting to get the twinwall temperature up more than about 1F. So, I am inclined to believe that all three temperatures above are correct (or close) and that the twinwall is really quite a bit cooler than the thermocouple because the thermocouple is opaque and absorbing more solar radiation than the twinwall. Any thoughts on this?
I'll probably try this again when the sun is not shining on the collector and see if the readings get closer together.
IR picture of thermocouple (the bright spot with the wire leading to it), and the surrounding twinwall.
Update: I did get a number from FLIR for the emissivity of polycarbonate -- it is 0.95. This leads me to believe that the best estimate of glazing temperature in the examples above are the temperatures that the IR camera shows with the emissivity set to 0.95. Perhaps a lesson here is that you have to be careful using the trick of putting a bit of tape on a surface that you don't know the emissivity of in order to get an accurate surface temperature with an IR camera or IR temperature gage. If you are in the sun, the difference in absorptivity of the tape and the surface the tape is on will cause the tape to run at a different temperature -- it won't give a true reading of the surface temperature. |
Gary
January 18, 2012